Vault Pak™ - Sand Filtration
The AF Series Vault-Pak™ is a cost-effective pre-engineered equipment vault, with an integral sand filter, that is designed for small to medium water features. Efficient layout and top access make it easy to maintain and service.
Standard Features:
• Heavy-duty FRP enclosure with 2” floor drain.
• Structurally engineered and certified for in-ground installation.
• 18” sand filter with multi-port valve for fountains up to 7,500 gallons
(sand not included).
• Thermally protected pump.
• All necessary isolation and check valves.
• Pressure gauge.
• Power distribution panel and time clock.
• 110 CFM forced air ventilation fan.
• Lockable lid with lock-open arm, stainless steel lock hasp, and stainless steel hinge.
• Wall mounted maintenance procedures for all equipment.
• Stainless steel anchors and tie-down cables.
Optional Features:
• To add one 120 volt GFCI protected lighting circuit (rated at 1,800 watts) with one time clock, add suffix –L1 to catalog number.
• To add two 120 volt GFCI protected lighting circuits (rated at 1,800 watts each) with one time clock, add suffix –L2 to catalog number.
Note: Add 20 amps for each lighting circuit added to the total service amperage load requirement.
To Select the Appropriate Vault-Pak™:
1. Determine the total flow requirement by combining the total flow rate (GPM) required by all nozzles, then add 20 GPM for the filter, plus a 10% safety factor.
2. Determine the total pump pressure requirement by taking the single highest nozzle head pressure requirement and adding a system friction loss allowance. An allowance of 25 feet of head pressure is adequate for simple piping systems with piping runs no longer than 75 feet. If the fountain system contains pools of different elevations, long piping runs, or more than a few nozzles, it is recommended that the pump pressure requirement be fully calculated.
3. Locate the point on the performance chart where the total flow determined in Step and the total head pressure requirement determined in Step intersect. Any pump performance curve that passes above this point can be used. If this point is on or very near a curve, it is recommended that the next higher curve be used.
Installation Information: For additional information on selection and installation of equipment, see the Technical & Safety section, below.
|
|

|
|
|
|
|
|
Required Amperage |
Model Number |
Pump
HP |
Max. GPM
@ 50' Hd |
Max. LPM
@ 1.5 Bar |
115VAC/
60Hz |
230VAC/
60Hz |
PFV-AF075 |
.75 |
80 |
303 |
13.8 |
6.9 |
PFV-AF100 |
1 |
95 |
360 |
16 |
8 |
PFV-AF200 |
2 |
145 |
549 |
24 |
12 |
| 1. Data are fo 60 Hertz pump.
|
|
|
Vault Pak™ - Cartridge Filtration
An AC Series Vault-Pak™ incorporates cartridge filtration into a cost-effective pre-engineered equipment vault for small to medium water features. Efficient layout and top access make it easy to maintain and service.
Standard Features:
• Heavy-duty FRP enclosure with 2” floor drain.
• Structurally engineered and certified for in-ground installation.
• 25 square foot cartridge filter with spare element for fountains up to 3,300 gallons.
• Thermally protected pump.
• All necessary isolation and check valves.
• Pressure gauge.
• Power distribution panel and time clock.
• 110 CFM forced air ventilation fan.
• Lockable lid with lock-open arm, stainless steel lock hasp, and stainless steel hinge.
• Wall mounted maintenance procedures for all equipment.
Optional Features:
• To add one 120 volt GFCI protected lighting circuit (rated at 1,800 watts) with one time clock, add suffix –L1 to catalog number.
• To add two 120 volt GFCI protected lighting circuits (rated at 1,800 watts each) with one time clock, add suffix –L2 to catalog number.
Note: Add 20 Amps for each lighting circuit added to the total service amperage load requirement.
To Select the Appropriate Vault-Pak™:
1. Determine the total flow requirement by combining the total flow rate (GPM) required by all nozzles, then add 20 GPM for the filter, plus a 10% safety factor.
2. Determine the total pump pressure requirement by taking the single highest nozzle head pressure requirement and adding a system friction loss allowance. An allowance of 25 feet of head pressure is adequate for simple piping systems with piping runs no longer than 75 feet. If the fountain system contains pools of different elevations, long piping runs, or more than a few nozzles, it is recommended that the pump pressure requirement be fully calculated.
3. Locate the point on the performance chart where the total flow determined in Step 1 and the total head pressure requirement determined in Step 2, intersect. Any pump performance curve that passes above this point can be used. If this point is on or very near a curve, it is recommended that the next higher curve be used.
Installation Information: For additional information on selection and installation of equipment, see the Technical & Safety section, below.
|
|

|
|
|
|
|
|
Required Amperage |
Model Number |
Pump
HP |
Max. GPM
@ 50' Hd |
Max. LPM
@ 1.5 Bar |
115VAC/
60Hz |
230VAC/
60Hz |
PFV-AC075 |
.75 |
80 |
303 |
13.8 |
6.9 |
PFV-AC100 |
1 |
95 |
360 |
16 |
8 |
PFV-AC200 |
2 |
145 |
549 |
24 |
12 |
| 1. Data are fo 60 Hertz pump.
|
|
|
Skid Pak™ - Cartridge Filtration
The Skid-Pak™ with its integral cartridge filter is a cost-effective pre-engineered equipment package for small to medium water features. Its small footprint requires minimal equipment room space and its efficient layout makes it easy to maintain
and service.
Standard Features:
• Single piece, all welded steel frame with integral mounting pads and a corrosion
resistant finish.
• 50 square foot cartridge filter with spare element for fountains up to 7,500 gallons.
• Thermally protected pump.
• All necessary isolation and check valves.
• Pressure gauge.
• Power distribution panel and time clock.
• Skid mounted maintenance procedures for all equipment.
Optional Features:
• To add one 120 volt GFCI protected lighting circuit (rated at 1,800 watts) with one time clock, add suffix –L1 to catalog number.
• To add two 120 volt GFCI protected lighting circuits (rated at 1,800 watts each) with one time clock, add suffix –L2 to catalog number.
Note: Add 20 Amps for each lighting circuit added to the total service amperage load requirement.
• For a stainless steel skid, add suffix –SS to catalog number.
To Select the Appropriate Vault-Pak™:
1. Determine the total flow requirement by combining the total flow rate (GPM) required by all nozzles, then add 20 GPM for the filter, plus a 10% safety factor.
2. Determine the total pump pressure requirement by taking the single highest nozzle head pressure requirement and adding a system friction loss allowance. An allowance of 25 feet of head pressure is adequate for simple piping systems with piping runs no longer than 75 feet. If the fountain system contains pools of different elevations, long piping runs, or more than a few nozzles, it is recommended that the pump pressure requirement be fully calculated.
3. Locate the point on the performance chart where the total flow determined in Step 1
and the total head pressure requirement determined in Step 2, intersect. Any pump performance curve that passes above this point can be used. If this point is on or very near a curve, it is recommended that the next higher curve be used.
Installation Information: For additional information on selection and installation of equipment, see the Technical & Safety section, below.
|
|

|
|
|
|
|
|
Required Amperage |
Model Number |
Pump
HP |
Max. GPM
@ 50' Hd |
Max. LPM
@ 1.5 Bar |
115VAC/
60Hz |
230VAC/
60Hz |
PFF-AC075 |
.75 |
80 |
303 |
13.8 |
6.9 |
PFF-AC100 |
1 |
95 |
360 |
16 |
8 |
PFF-AC200 |
2 |
145 |
549 |
24 |
12 |
| 1. Data are fo 60 Hertz pump.
|
|
|
The Waterbox™ Submersible Fountain System is a complete pre-assembled, self-contained unit designed for installation in a concrete pool floor. Simply place the unit in position - with the top surface at the elevation of the finished pool floor - make electrical, piping, and drain connections, secure for concrete pour, and pour.
Standard Features:
• Housing is heavy-duty FRP (WB-16/22) or ABS (WB-12).
• Includes pump(s), junction box, potting compound, and regulating valve.
• Drain fitting has an extended ‘T’ handle for ease of maintenance.
• Pumps and junction boxes are U.L. Listed for fountain applications.
Selecting the Appropriate Waterbox™:
• Use the WB-12 for wall fonts and other low demand features.
• Use the WB-16 and WB-22 with bowl fountains and stream and waterfall features.
Model Number |
|
@ft. Hd. |
Amps
@115V/1Ø 60Hz |
WB-12 |
14 |
15 |
5 |
WB-16-080 |
80 |
15 |
14 |
WB-16-090 |
90 |
20 |
8* |
WB-22-160 |
160 |
15 |
28 |
WB-22-180 |
180 |
20 |
16* |
*Unit requires 240V/1Ø/60Hz |
|
Dimensions |
Model Number |
A Inches |
B Inches |
A cm |
B cm |
WB-12 |
16 |
14.5 |
41 |
37 |
WB-16-080 |
13.75 |
27.5 |
35 |
70 |
WB-16-090 |
13.75 |
27.5 |
35 |
70 |
WB-22-160 |
18.25 |
33.5 |
46 |
85 |
WB-22-180 |
18.25 |
33.5 |
46 |
85 |
*Unit requires 240V/1Ø/60Hz
|
Model Number |
|
@ Bar |
Amps
@110V/1Ø 50Hz |
WB-16-080/50 |
80 |
15 |
10 |
WB-16-090/50 |
90 |
20 |
5.8* |
WB-22-160/50 |
160 |
15 |
20 |
WB-22-180/50 |
180 |
20 |
11.6* |
*Unit requires 220V/1Ø/50Hz
|
|
Dimensions |
Model Number |
A Inches |
B Inches |
A cm |
B cm |
WB-16-080/50 |
13.75 |
27.5 |
35 |
70 |
WB-16-090/50 |
13.75 |
27.5 |
35 |
70 |
WB-22-160/50 |
18.25 |
33.5 |
46 |
85 |
WB-22-180/50 |
18.25 |
33.5 |
46 |
85 |
|
|

|
|
|
|